| A vast range of cocooned generators to fulfill any marine application |
|
 |
AC or DC Machines |
 |
High Speed or Slow Speed |
 |
50 or 60 Hz |
 |
Single or Three Phase |
 |
Water Cooled |
 |
Marine |
|
|
 |
|
| SUPPLIED COMPLETE WITH ACOUSTIC COCOON |
MODEL MODELL |
KVA |
KW |
Hz |
PHASE |
VOLTS |
COVER DIMS. HAUBE MM L x W x H |
DRY WEIGHT GEWICHT |
ENGINE MOTOR |
Kg |
LbS |
H1W4FIC |
4 |
3.6 |
50 |
1 |
230 |
550 x 420 x 530 |
94 |
207 |
Farymann 18W |
H2W6MIC |
6 |
6 |
50 |
1 |
230 |
690 x 550 x 610 |
149 |
328 |
Mitsubishi L2E |
H2W8MIC |
8 |
7.2 |
50 |
1 |
230 |
740 x 550 x 590 |
172 |
378 |
Mitsubishi L2E |
H1W4FI6C |
4 |
3.6 |
60 |
1 |
120/240 |
550 x 420 x 530 |
94 |
207 |
Farymann 18W |
H2W6MI6C |
6 |
6 |
60 |
1 |
120/240 |
690 x 550 x 610 |
149 |
328 |
Mitsubishi L2E |
H2W8MI6C |
8 |
7.2 |
60 |
1 |
120/240 |
740 x 550 x 590 |
172 |
378 |
Mitsubishi L2E |
|
|
 |
|
| SUPPLIED COMPLETE WITH ACOUSTIC COCOON |
MODEL MODELL |
KVA |
KW |
Hz |
PHASE |
VOLTS |
COVER DIMS. HAUBE MM L x W x H |
DRY WEIGHT GEWICHT |
ENGINE MOTOR |
Kg |
LbS |
|
3.5 |
3.5 |
50 |
1 |
220 |
760
x 470 x 500 |
85 |
187 |
Farymann 18W |
H2M6MIC |
6 |
6 |
50 |
1 |
230 |
820 x 550 x
625 |
148 |
326 |
Mitsubishi L2E |
H2E7.2MIC |
7.2 |
6.5 |
50 |
1 |
230 |
950 x 550 x
625 |
179 |
394 |
Mitsubishi L2E |
H3E9MIC |
9 |
7.2 |
50 |
1 |
230 |
1050 x
550 x 685 |
196 |
430 |
Mitsubishi
L3E |
H3E11MIC |
11 |
8.8 |
50 |
1 |
230 |
1120 x 550 x
685 |
220 |
484 |
Mitsubishi
L3E |
H3E15MIC |
15 |
12 |
50 |
1 |
230 |
1010 x
575 x 700 |
275 |
605 |
Mitsubishi
S3L2 |
H3E14MIC |
14 |
11 |
50 |
3 |
230/400 |
1120 x
550 x 685 |
220 |
484 |
Mitsubishi
L3E |
H2M7M16C |
6.5 |
6.5 |
60 |
1 |
120/240 |
820
x 550 x 625 |
148 |
326 |
Mitsubishi L2E |
H2E8M16C |
8 |
7.2 |
60 |
1 |
120/240 |
950
x 550 x 625 |
179 |
394 |
Mitsubishi L2E |
H3E12M16C |
12 |
9.6 |
60 |
1 |
120/240 |
1120 x
550 x 685 |
220 |
484 |
Mitsubishi
L3E |
H3E16MI6C |
16 |
12.8 |
60 |
1 |
120/240 |
1010 x
575 x 700 |
275 |
605 |
Mitsubishi
S3L2 |
H3E15M36C |
15 |
12 |
60 |
3 |
127/220 |
1120 x 550 x
685 |
220 |
484 |
Mitsubishi
L3E |
|
|
 |
|
| SUPPLIED COMPLETE WITH ACOUSTIC ENCLOSURE |
MODEL MODELL |
KVA |
KW |
Hz |
PHASE |
VOLTS |
SET DIMS. ABMESSUNG L x W x H |
COVER DIMS. HAUBE MM L x W x H |
DRY WEIGHT GEWICHT |
ENGINE MOTOR |
Kg |
LbS |
H4M20MIC |
20 |
16 |
50 |
1 |
230 |
1095
x 470 x 660 |
1170
x 540 x 680 |
280 |
616 |
Mitsubishi S4L2 |
H4M25M3C |
25 |
20 |
50 |
3 |
230/400 |
1095 x 470 x
660 |
1170 x 540 x
680 |
280 |
616 |
Mitsubishi S4L2 |
|
|
 |
|
| RESILIENTLY MOUNTED ON STEEL DRIP TRAY. OPTIONAL ACOUSTIC ENCLOSURE |
MODEL MODELL |
KVA |
KW |
Hz |
PHASE |
VOLTS |
SET DIMS. ABMESSUNG L x W x H |
COVER DIMS. HAUBE MM L x W x H |
DRY WEIGHT GEWICHT |
ENGINE MOTOR |
Kg |
LbS |
H2M6M1 |
6 |
6 |
50 |
1 |
230 |
750
x 460 x 570 |
850
x 540 x 600 |
135 |
297 |
Mitsubishi
L2E |
H2E7.2M1 |
7.2 |
6.5 |
50 |
1 |
230 |
880
x 460 x 570 |
990 x 540 x
600 |
166 |
365 |
Mitsubishi
L2E |
H2E8M3 |
8 |
8 |
50 |
3 |
230/400 |
880
x 460 x 570 |
990
x 540 x 600 |
169 |
372 |
Mitsubishi
L2E |
H3E9M1 |
9 |
7.2 |
50 |
1 |
230 |
950
x 460 x 590 |
1050 x 540 x
620 |
220 |
484 |
Mitsubishi
L3E |
H3E11M1 |
11 |
8.8 |
50 |
1 |
230 |
1010
x 460 x 590 |
1110
x 540 x 620 |
235 |
517 |
Mitsubishi
L3E |
H3E15M3 |
15 |
12 |
50 |
3 |
230/400 |
1010 x
460 x 590 |
1110 x 540 x
620 |
235 |
517 |
Mitsubishi
L3E |
H2M7M16 |
6.5 |
6.5 |
60 |
1 |
120/240 |
750
x 460 x 570 |
850
x 540 x 600 |
135 |
297 |
Mitsubishi
L2E |
H2E8M16 |
8.2 |
7.4 |
60 |
1 |
120/240 |
880
x 460 x 570 |
990 x 540 x
600 |
169 |
372 |
Mitsubishi
L2E |
H3E15M36 |
15 |
12 |
60 |
3 |
230/400 |
1010
x 460 x 590 |
1110
x 540 x 620 |
223 |
490 |
Mitsubishi
L3E |
|
|
 |
|
| SUPPLIED RESILIENTLY MOUNTED ON A STEEL DRIP TRAY, OPTIONAL ACOUSTIC ENCLOSURE |
MODEL MODELL |
KVA |
KW |
Hz |
PHASE |
VOLTS |
SET DIMS. ABMESSUNG L x W x H |
COVER DIMS. HAUBE MM L x W x H |
DRY WEIGHT GEWICHT |
ENGINE MOTOR |
Kg |
LbS |
H4M40C35 |
40 |
32 |
50 |
3 |
230/400 |
1545
x 660 x 880 |
1650
x 730 x 900 |
670 |
1474 |
Cummins
4B |
H4M50C35 |
50 |
40 |
50 |
3 |
230/400 |
1545
x 720 x 880 |
1650 x
730 x 900 |
740 |
1628 |
Cummins
4BT |
H6M60C35 |
60 |
48 |
50 |
3 |
230/400 |
1895
x 700 x 880 |
2000
x 750 x 900 |
950 |
2090 |
Cummins
6B |
H6M85C35 |
85 |
68 |
50 |
3 |
230/400 |
1895
x 640 x 880 |
2000
x 750 x 900 |
950 |
2090 |
Cummins
6BT |
H6M102C35 |
102 |
82 |
50 |
3 |
230/400 |
1940
x 640 x 880 |
2100
x 750 x 900 |
980 |
2156 |
Cummins
6BT |
H4M66C36 |
66 |
53 |
60 |
3 |
127/220 |
1545 x
660 x 880 |
1650 x
730 x 900 |
740 |
1628 |
Cummins
4BT |
H6M130C36 |
130 |
104 |
60 |
3 |
127/220 |
1895
x 640 x 880 |
2000
x 750 x 900 |
950 |
2090 |
Cummins
6BT |
Weights Quoted Include Optional Acoustic Enclosure |
|
|
GENERATOR SELECTION
The selection of a power generator requires a decision based upon engine speed verses noise, weight and cost. |
|
| A slow speed machine is more readily silenced since its bulk is only partially used for power generation. |
|
| High speed generators are superior in terms of electrical starting power, power to weight ratio and price. Most high speed diesels are more fuel efficient which makes them more “environmentally friendly”. |
|
Typical Consumers Power Consumption |
USEFUL INFORMATION |
WATTS |
AMPS |
Battery Charger |
Batterie Lader |
500 - 2,000 |
2.2 - 9 |
Freezer |
kuhltruhe |
600 -
800 |
2.7 -
3.6 |
T.V. |
Fernseher |
100 -
200 |
0.4
- 1 |
Kettle |
Kessel |
1,500 -
3,500 |
6.8
- 15 |
Hairdryer |
Fohn |
300 -
750 |
1.3
- 3.4 |
Fan |
Ventilator |
50 -
150 |
0.2 -
0.6 |
Air
Conditioner |
Klima
Anlage |
700 -
3,500 |
3.1
- 15 |
Cooker |
Kocher |
800 -
6,000 |
3.6
- 27 |
Heater |
Warmlufter |
1,000 -
3,000 |
4.5
- 13.6 |
|
|
Dimensions & specifications are subject to change.
NOTES
1,000 Watts = 4.3 Amps at 230 Volts
KW = KVA X Power Factor
Most Air Conditioners and Inductive Motors have a starting current that is approx. 3 to 6 times the running current.
|
|
 |
|
Marine Generators Available from 3.5 KVA to 130 KVA
|
|
|
 |
|
|
 |
|